Show simple item record

dc.contributor.advisorMaldonado Gualdron, Juan Fernandospa
dc.contributor.authorInfante Ramos, Gerardo Carlos
dc.contributor.authorCenteno Baez, Angelina
dc.date.accessioned2015-01-27T14:08:11Z
dc.date.accessioned2015-07-13T19:15:48Z
dc.date.accessioned2019-12-30T18:56:29Z
dc.date.available2015-01-27T14:08:11Z
dc.date.available2015-07-13T19:15:48Z
dc.date.available2019-12-30T18:56:29Z
dc.date.issued2013-11-13
dc.identifier.urihttp://hdl.handle.net/10654/12377
dc.description.abstractEl numero creciente de procedimientos bajo anestesia general que ameritan asegurar la via aerea con un tubo endotraqueal, y que pese a elementos de seguridad creados, no exite la cultura del uso del mismo en donde es el carácter subjetivo de medicion el usado, razon por la que se comparo según la poblacon estudiada si estos metodos subjetivos son seguros para el paciente y si son equiparables con la medicon cuantitativa que es la que deberia usarse. En donde hay reportes que presiones elevadas en peridos cortos de tiempo se asocian a ecuelas tipo estenosis, ademas en nuestro caso en el Hospital militar los pacientes son sometidos a multiples procedimientos incluso dia de por medio en donde la anestesia general es la empleada tambien en multiples casos, por lo que no se conoce cual es el impacto que se tiene en este tipo de pacientes y sobre todo cuanto es la real presion a la que se somete la mucosa traqueal que afecte su perfusion y predisponga a estenosis o a lesiones futuras.spa
dc.formatpdfspa
dc.format.mimetypepdfspa
dc.language.isospaspa
dc.publisherUniversidad Militar Nueva Granadaspa
dc.titlePresión del neumotaponador en los pacientes adultos sometidos a anestesia general con intubación orotraqueal en el Hospital Militar Central de Bogotá.spa
dc.typeinfo:eu-repo/semantics/bachelorThesisspa
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessspa
dc.subject.lembANESTESIOLOGIAspa
dc.subject.lembANESTESIA-COMPLICACIONESspa
dc.subject.lembINTUBACION OROTRAQUEALspa
dc.publisher.departmentFacultad de Medicinaspa
dc.type.localTrabajo de gradospa
dc.description.abstractenglishThe growing number of procedures under general anesthesia that merit ensure the airway with an endotracheal tube, and despite security elements created, not exite the culture of using thereof wherein is the subjective nature of measurement used, reason why was compared according to the poblacon studied if these subjective methods are safe for the patient and if they are comparable with quantitative medicon which is what should be used. Where there are reports that elevated pressures in short peridos time associated with ecuelas stenosis type, also in our case in the military hospital patients undergo multiple procedures even day by where general anesthesia is used also in multiple cases, so it is not known what impact you have in these patients and all that is real pressure on the tracheal mucosa affecting its perfusion and predisposes stenosis or undergoes further injury.eng
dc.title.translatedEndotraqueal pressure in patients undergoing general anesthesia with orotracheal intubation in the Military Hospital Central de Bogotá.spa
dc.subject.keywordsendotraqueal pressurespa
dc.subject.keywordsgeneral anesthesiaspa
dc.publisher.programAnestesiologíaspa
dc.creator.degreenameEspecialista en Anestesiologíaspa
dc.subject.proposalpresion neumotaponadorspa
dc.subject.proposalanestesia generalspa


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record