Sistema de electrocoagulación como tratamiento de aguas residuales galvánicas
dc.creator | Morales Posada, Nelly Bibiana | |
dc.creator | Acosta Niño, Gema Eunice | |
dc.date | 2010-06-01 | |
dc.identifier | https://revistas.unimilitar.edu.co/index.php/rcin/article/view/282 | |
dc.identifier | 10.18359/rcin.282 | |
dc.description | This paper shows the second phase of the project “Implementation and Evaluation of an Electro-coagulation pilot test as Treatment of Wastewater to be reused. Case Study: Industrial Wastewater Galvanic source.” For its development, a prototype located at the University was evaluated and optimized from wastewater tests, implementing a percentage higher than 47 % to remove heavy metals, such as Cr+6, Pb and Zn by electro-coagulation. This study used to 10 L wastewater from Compañía Eléctrica Ltd. was used. Analysis was made by comparing Cu, Cr, Cr+6, Ni, Pb and Zn parameters before and after electro-coagulation treatment. There was a Cr 51,65 % decrease, where value achieved is below standards set regarding waste (Resolution No 1074 28 Oct. 1997), Ni 18,09 %, Pb 50 %, Zn 47,37 %, despite their removal have produced higher values than legislation parameters. There was a Cu 519,48 % increasing due to the plate used by treatment. Average values during tests were pH: 3,18; conductivity: 21,83 mS/m; and temperature: 48,5ºC. Although variable and parameter values are not generally within those given in accordance to literature with wastewater electro-coagulation, there was a significant reduction in the presence of metals studied. | en-US |
dc.description | El presente artículo muestra la segunda fase del proyecto "Implementación y evaluación de un sistema piloto de electrocoagulación como tratamiento de aguas residuales con fines de reuso. Estudio de caso: aguas residuales industriales de origen galvánico". Para su desarrollo, se valoró y optimizó un prototipo existente en la Universidad, a partir de ensayos realizados en aguas residuales con contenido de metales, implementando un porcentaje mayor al 47% para la remoción de metales pesados como Cr+6, Pb y Zn de tales aguas, mediante proceso de electrocoagulación. Para el estudio, se utilizaron 10L de agua residual correspondientes al vertimiento de la empresa Compañía Eléctrica Ltda. Los análisis se hicieron, mediante la confrontación de parámetros de Cu, Cr, Cr+6, Ni, Pb y Zn, antes y después del tratamiento de electrocoagulación. Se obtuvo una reducción en Cr del 51.65%, donde el valor arrojado está por debajo de los estándares establecidos en materia de vertimientos (Res. No 1074 28 Oct. 1997), Ni del 18.09%, Pb del 50%, Zn del 47.37%, los cuales a pesar de la remoción producida, tienen valores superiores a lo estipulado en esta normativa. El Cu tuvo un aumento del 519.48%, debido a la placa empleada para el tratamiento. Los valores promedio obtenidos durante los ensayos fueron: pH: 3.18, conductividad: 21.83 mS/m y temperatura: 48.5 ºC. A pesar de que los valores de las variables y los parámetros no se encuentran dentro de los rangos generalmente expuestos por la literatura consultada para sistemas de electrocoagulación con aguas residuales, se obtuvo una reducción relevante en cuanto a la presencia de los metales estudiados. | es-ES |
dc.format | application/pdf | |
dc.format | text/html | |
dc.language | spa | |
dc.publisher | Universidad Militar Nueva Granada | es-ES |
dc.relation | https://revistas.unimilitar.edu.co/index.php/rcin/article/view/282/92 | |
dc.relation | https://revistas.unimilitar.edu.co/index.php/rcin/article/view/282/1923 | |
dc.relation | /*ref*/Equipo profesional de Propel Fundes Colombia. (2001). Guía de Buenas Prácticas para el Sector Galvanotécnia. Bogotá, D.C. Ministerio del Medio Ambiente y Fundes Colombia. | |
dc.relation | /*ref*/Compa-ía Eléctrica Ltda. (2010). Galvanización en caliente. Página consultada el 23 de marzo de 2010. En: http://www.companiaelectrica.com/paginas/galvanizado.1.html | |
dc.relation | /*ref*/Mollah M., Schennach R., Parga J. y Cocke D. (2001) Electrocoagulation (EC)– Science and applications; En: Journal of hazardous materials, Vol.84 Nº1, pp.29-41. http://dx.doi.org/10.1016/S0304-3894(01)00176-5 | |
dc.relation | /*ref*/Galco S.A. (2010). Soluciones con ingeniería. Página consultada el 8 de abril de 2010. En: http://www.galcosa.com/lineas.html | |
dc.relation | /*ref*/Rajeshwar K. y Ibá-ez J., (1997). Environmental electrochemistry: Fundamentals and Applications in Pollution Abatement. San Diego, California: Academic Press Limited, 410p. | |
dc.relation | /*ref*/Holt P., Barton G. y Mitchell C. (2005) The future for electrocoagulation as a localised water treatment technology; En: Chemosphere, Vol. 59 Nº3, pp. 355-367. http://dx.doi.org/10.1016/j.chemosphere.2004.10.023 | |
dc.relation | /*ref*/Restrepo A., Arango Á. y Garcés L. (2006) La Electrocoagulación: retos y oportunidades en el tratamiento de aguas; En: Producción + limpia, Vol.1 Nº2, pp.58-77. | |
dc.relation | /*ref*/Stephenson R. y Tennant B. (2003) New electrocoagulation process treats emulsified oily wastewater at Vancouver Shipyards; En: Environmental Science & Engineering Magazine. Disponible en: http://www.esemag.com/0103/electro.html | |
dc.relation | /*ref*/Aristizábal A y Bermúdez M. (2007) Estudio de la factibilidad de un sistema de electrocoagulación para tratamiento de aguas procedentes de lavanderías industriales con fines de reuso; Medellín. Trabajo de Grado (Ingeniero Químico).Universidad Pontificia Bolivariana; Facultad de Ingeniería. | |
dc.relation | /*ref*/Chen, G. (2004) Electrochemical technologies in wastewater treatment; En:Separation and Purification Technology, Vol.38 Nº1, pp.11–41.Mercado, I., http://dx.doi.org/10.1016/j.seppur.2003.10.006 | |
dc.relation | /*ref*/Adhoum, N. y and Monser, L. (2004) Decolourization and removal of phenolic compounds from olive mill wastewater by electrocoagulation; En: Chemical Engineering and Processing, Vol.43 Nº10, pp.1281-1287. http://dx.doi.org/10.1016/j.cep.2003.12.001 | |
dc.relation | /*ref*/Bayramoglu M., Mehmet K., Orhan T. y Mustafa S. (2004) Operating cost analysis of electrocoagulation of textile dye wastewater. En: Separation and Purification Technology, Vol.37 Nº2, pp.117–125. http://dx.doi.org/10.1016/j.seppur.2003.09.002 | |
dc.relation | /*ref*/Kumar P., Chaudhari S., Khilar K. y Mahajan S. (2004) Removal of arsenic from water by electrocoagulation; En: Chemosphere, Vol.55 Nº9, pp.1245–1252. http://dx.doi.org/10.1016/j.chemosphere.2003.12.025 | |
dc.relation | /*ref*/Holt P., Barton G. y Mitchell C. (1999) Electrocoagulation as a Wastewater Treatment; En: ANNUAL AUSTRALIAN ENVIRONMENTAL ENGINEERING RESEARCH. Proccedings The Third Annual Australian Environmental Engineering Research Event. Castlemaine, Victoria. | |
dc.relation | /*ref*/Mercado I., Reyes D. y Morante G. (2006) La electroquímica en función de la ingeniería ambiental. Método de electrocoagulación aplicado a un flujo continúo de residuos líquidos. En: Residuos. A-o Nº16 Nº94, pp. 62-65. | |
dc.relation | /*ref*/Chen L. y Sheng L. (2004) Treatment of chemical mechanical polishing wastewater by electrocoagulation: system performances and sludge settling characteristics. En:Chemosphere, Vol.54 Nº3, pp. 235–242. http://dx.doi.org/10.1016/j.chemosphere.2003.08.014 | |
dc.relation | /*ref*/Adhoum N. (2004) Treatment of electroplating wastewater containing Cu2+, Zn2+ and Cr(VI) by electrocoagulation. En: Journal of Hazardous Materials, Vol.112 Nº3, pp.207-213. http://dx.doi.org/10.1016/j.jhazmat.2004.04.018 | |
dc.relation | /*ref*/DEPARTAMENTO TÉCNICO ADMINISTRATIVO DEL MEDIO AMBIENTE, DAMA.(1997). Resolución Nº 1074 28 de Octubre de 1997. Bogotá, D.C. | |
dc.relation | /*ref*/Jiang J. (2002) Laboratory study of electro-coagulation–flotation for water treatment. En: Water Research, Vol.36 Nº16, pp.4064– 4078. http://dx.doi.org/10.1016/s0043-1354(02)00118-5 | |
dc.rights | Derechos de autor 2016 Ciencia e Ingeniería Neogranadina | es-ES |
dc.source | Ciencia e Ingenieria Neogranadina; Vol. 20 No. 1 (2010); 33-44 | en-US |
dc.source | Ciencia e Ingeniería Neogranadina; Vol. 20 Núm. 1 (2010); 33-44 | es-ES |
dc.source | Ciencia e Ingeniería Neogranadina; v. 20 n. 1 (2010); 33-44 | pt-BR |
dc.source | 1909-7735 | |
dc.source | 0124-8170 | |
dc.subject | Galvanic wastes waters | en-US |
dc.subject | Electrocoagulation | en-US |
dc.subject | Heavy metals | en-US |
dc.subject | Electrolytic cell. | en-US |
dc.subject | aguas residuales galvánicas | es-ES |
dc.subject | electrocoagulación | es-ES |
dc.subject | metales pesados | es-ES |
dc.subject | celda electrolítica | es-ES |
dc.title | Electrocoagulation system as treatment of galvanic wastewa | en-US |
dc.title | Sistema de electrocoagulación como tratamiento de aguas residuales galvánicas | es-ES |
dc.type | info:eu-repo/semantics/article | |
dc.type | info:eu-repo/semantics/publishedVersion |
Archivos en el ítem
Archivos | Tamaño | Formato | Ver |
---|---|---|---|
No hay archivos asociados a este ítem. |