dc.descriptionNowadays the great constructions of Colombia and the world, especially road infrastructure, have encouraged the use of high-strength concrete. The use of post-installed anchors has also grown simultaneously in all concrete structures. Therefore an experimental procedure was developed in this investigation to assess post-installed anchor systems based on tensile test specimens with high strength concrete. The evaluation considers the analysis of the tensile tests results of test pieces with an anchoring system for three lengths (6, 9 and 12 times the diameter of the rod) with two rod diameters (3/8” y 5/8”) in two types of high-strength concrete (5000Psi y 6000Psi) to determine the length and effective system load. The analysis carried out on the experimental test is to correlate the result of the maximum strength of steel reinforcement used (fy = 4200Psi) with the variables post anchor system installed. The results obtained are the percentage of system resistance depending on anchor length; the length that ensures steel fluency and their correlations between the percentage of effective resistance reached for each anchorage length and the use of high strength concrete. With the above parameters, the contribution of high strength concretes to the efficiency of the installed anchorage systems was analyzed.eng
dc.descriptionHoy en día, las grandes construcciones de Colombia y el mundo, y en especial las de infraestructura vial, han fomentado el uso de concretos de alta resistencia; también ha crecido de forma simultánea el uso de los anclajes posinstalados en todas las estructuras de concreto. Por lo anterior, se desarrolló en esta investigación un procedimiento experimental para evaluar sistemas de anclaje posinstalados, basado en ensayos a tracción con probetas de concreto de alta resistencia. La evaluación considera el análisis de los resultados de los ensayos a tracción de probetas con un sistema de anclaje para tres longitudes (6, 9 y 12 veces el diámetro de la varilla) con dos diámetros de varilla (3/8” y 5/8”) en dos calidades de concreto de alta resistencia (5000Psi y 6000Psi), para determinar la longitud y carga efectiva del sistema. El análisis que se realiza al ensayo experimental es correlacionar el resultado de la carga máxima de fluencia del acero de refuerzo utilizado (fy=4200Psi) con las variables del sistema de anclaje posinstalado. Con esto se obtuvo como resultados el porcentaje de resistencia del sistema en función de la longitud de anclaje, la longitud efectiva que garantiza la fluencia del acero y las correlaciones entre el porcentaje de resistencia efectiva alcanzada para cada longitud de anclaje con el uso de concreto de alta resistencia. Con los anteriores parámetros se analizó el aporte de los concretos de alta resistencia a la eficiencia de los sistemas de anclajes posinstalados.spa
dc.formatapplication/pdf
dc.formattext/html
dc.formatapplication/msword
dc.language.isospa
dc.publisherUniversidad Militar Nueva Granadaspa
dc.rightsDerechos de autor 2017 Ciencia e Ingeniería Neogranadinaspa
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/4.0spa
dc.sourceCiencia e Ingenieria Neogranadina; Vol 27 No 2 (2017); 137-156eng
dc.sourceCiencia e Ingeniería Neogranadina; Vol. 27 Núm. 2 (2017); 137-156spa
dc.sourceCiencia e Ingeniería Neogranadina; v. 27 n. 2 (2017); 137-156por
dc.source1909-7735
dc.source0124-8170
dc.titleAnchors post-installed in high strength concreteeng
dc.titleAnclajes posinstalados en concretos de alta resistenciaspa
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.relation.referenceshttp://revistas.unimilitar.edu.co/index.php/rcin/article/view/2208/2491
dc.relation.referenceshttp://revistas.unimilitar.edu.co/index.php/rcin/article/view/2208/2665
dc.relation.referenceshttp://revistas.unimilitar.edu.co/index.php/rcin/article/view/2208/3125
dc.relation.references/*ref*/A. Shah, Q. Ali, B. Alam, K. Shahzada et al., “Study on Performance Evaluation of Adhesive Anchors in Concrete,” International Journal of Advanced Structures and Geotechnical Engineering, vol. 1, no. 2, pp. 74-78, 2012.
dc.relation.references/*ref*/M. Obata, M. Inoue e Y. Goto, “The failure mechanism and the pull-out strength of a bond-type anchor near a free edge,” Mechanics of Materials, no. 28, pp. 113-122, 1998. https://doi.org/10.1016/S0167-6636(97)00052-5
dc.relation.references/*ref*/U. Priyank y S. Kimar, “Pull-out capacity of adhesive anchors: An analytical solution,” International Journal of Adhesion and Adhesives, no. 60, pp. 54-65, 2015. https://doi.org/10.1016/j.ijadhadh.2015.03.006
dc.relation.references/*ref*/L. Contrafatto y R. Cosenza, “Prediction of the pull-out strength of chemical anchors in natural stone,” Frattura ed Integrità Strutturale, no. 29, pp 196-208, 2014. https://doi.org/10.3221/IGF-ESIS.29.17
dc.relation.references/*ref*/A. Braimah, R. Guilbeault y E. Contestabile, “Strain rate behaviour of adhesive anchors in masonry,” Engineering Structures, vol. 67, pp. 96-108, 2014. https://doi.org/10.1016/j.engstruct.2014.02.018
dc.relation.references/*ref*/S. Yilmaz, M. A. Ozen e Y. Yardim, “Tensile behavior of post-installed chemical anchors embedded to low strength concrete,” Construction and Building Materials, vol. 47, pp. 861-866, 2013. https://doi.org/10.1016/j.conbuildmat.2013.05.032
dc.relation.references/*ref*/O. Caliskan, S. Yilmaz, H. Kaplan y N. Kirac, “Shear strength of epoxy anchors embedded into low strength concrete,” Construction and Building Materials, vol. 38, pp. 723-730, 2013. https://doi.org/10.1016/j.conbuildmat.2012.09.020
dc.relation.references/*ref*/G. Kwon, M. D. Engelhardt y R. E. Klingner, “Behavior of post-installed shear connectors under static and fatigue loading,” Journal of Constructional Steel Research, vol. 66, no. 4 pp. 532-541, 2010. https://doi.org/10.1016/j.jcsr.2009.09.012
dc.relation.references/*ref*/M. S. Hoehier, P. Mahrenholtz y R. Eligehausen, “Behavior of anchors in concrete at seismic-relevant loading rates,” ACI Structural Journal, vol. 108, pp. 238-247, 2011. https://doi.org/10.14359/51664259
dc.relation.references/*ref*/M. McVay, R. Cook y K. Krishnamurthy, “Pullout simulation of post installed chemically bonded anchors,” Journal Structural Engineering, vol. 122, no. 9, pp. 1016-1024, 2016. https://doi.org/10.1061/(asce)0733-9445(1996)122:9(1016)
dc.relation.references/*ref*/W. Dongpo, W. Dongsheng, H. Siming, Z. Jun y O. Chaojun, “Behavior of post-installed large-diameter anchors in concrete foundations,” Construction and Building Materials, vol. 95, pp. 124, 2015. https://doi.org/10.1016/j.conbuildmat.2015.07.129
dc.relation.references/*ref*/S. Yilmaz, M. A. Ozen y Y. Yardim, “Tensile behavior of post-installed chemical anchors embedded to low strength concrete,” Construction and Building Materials, vol. 47, pp. 861-866, 2013. https://doi.org/10.1016/j.conbuildmat.2013.05.032
dc.relation.references/*ref*/American Concrete Institute, “Manual de práctica del hormigón: Informe sobre el estado del arte de los anclajes en hormigón,” ACI 355.1R-91, Estados Unidos, 1997, pp. 355.1R-1-75.
dc.relation.references/*ref*/Argos, “Concreto de altas resistencias,” 2014. [En línea]. Disponible en: http://http://www.argos.co/Media/Colombia/images/Ficha%20t%C3%A9cnica%20Concreto%20Altas%20Resistencias.pdf
dc.relation.references/*ref*/Cemex, “Concretos especiales,” 2016 [En línea]. Disponible en: http://www.cemexcolombia.com/SolucionesConstructor/ConcretosEspeciales.aspx
dc.relation.references/*ref*/L. Rocha, “Concretos especiales en la construcción. Concretos de alta resistencia,” en Compilación de artículos de investigación octubre 2009. México, D. C.: Departamento de Materiales UAM, 2009, pp. 19-33.
dc.relation.references/*ref*/A. J. Murillo y E. Y. Salamanca, “Optimización de los materiales para hormigones de alta resistencia comprendidos entre 4000 Psi (28Mpa) – 6000 Psi (42 Mpa), sin aditivos,” Tesis de pregrado, Facultad de Ingeniería Civil, Universidad de la Salle, Bogotá, Colombia, 2006.
dc.relation.references/*ref*/Sika Colombia S.A., “Hoja técnica SikaPlast MO ®,” 2015. [En línea]. Disponible en: https://col.sika.com/dms/getdocument.get/16dbbdc1-a427-359c-b51d-b902ec1bb4fb/co-ht_SikaPlast%20MO.pdf
dc.relation.references/*ref*/Icontec. NTC 673 - Concretos. Ensayo de resistencia a la compresión de especímenes Cilíndricos de concreto. Bogotá, Colombia: Instituto Colombiano de Normas Técnicas y Certificación [Icontec], 2010.
dc.relation.references/*ref*/J. A. Galán y J. Hamón, “Estudio de la resistencia a tracción en anclajes estructurales post instalados con adhesivo epóxico,” Tesis de pregrado, Facultad de Ingeniería, Universidad Pedagógica y Tecnológica de Colombia, Tunja, Colombia, 2015.
dc.relation.references/*ref*/R. Cook y R. Konz, “Factors Influencing Bond Strength of adhesive Anchors,” ACI Structural Journal, vol. 98, no. 1, pp. 76- 85, 2001. https://doi.org/10.14359/10149
dc.relation.references/*ref*/A. Çolak, “Parametric study of factors affecting the pull-out strength of steel rods bonded into precast concrete panels,” International Journal of Adhesion and Adhesives,” vol. 21, no. 6, pp. 487-493, 2001. https://doi.org/10.1016/S0143-7496(01)00028-8
dc.relation.references/*ref*/Sika Colombia S.A., “Hoja técnica Sikadur AnchorFix-4 ®,” 2013. [En línea]. Disponible en: http://col.sika.com/es/rehabilitacion-y-reforzamiento/rehabilitar-reforzar/02a005/02a005sa01.html
dc.relation.references/*ref*/G. C. Mays, “Performance requirements for structural adhesives in relation to concrete strengthening,” International Journal of Adhesion and Adhesives, vol. 21, no. 5, pp. 423-429, 2001. https://doi.org/10.1016/S0143-7496(01)00019-7
dc.relation.references/*ref*/Icontec. NTC 2289 – Barras corrugadas y lisas de acero de baja aleación, para refuerzo de concreto. Bogotá, Colombia: Instituto Colombiano de Normas Técnicas y Certificación [Icontec], 2007.
dc.relation.references/*ref*/R. A. Cook, J. Kunz, W. Fuchs R. C. Konz, “Behavior and Design of single adhesive anchors under tensile load in uncracked concrete,” ACI Structural Journal, vol. 95, no. 1, pp.9-26, 1998. https://doi.org/10.14359/522
dc.relation.references/*ref*/R. A. Cook, “Behavior of chemically bonded anchors,” Journal of Structural Engineering, vol. 119, no. 9, pp. 2744-2762, 1993. https://doi.org/10.1061/(ASCE)0733-9445(1993)119:9(2744)
dc.relation.references/*ref*/R. Eligehausen, R. A. Cook y J. Appl, “Behavior and Design of Adhesive Bonded Anchors,” ACI Structural Journal, vol. 103, no. 6, pp.822-831, 2006. https://doi.org/10.14359/18234
dc.relation.references/*ref*/V. Romero, “Contrastación experimental de la resistencia de anclajes epóxicos,” Tesis de maestría, Facultad de Ingeniería, Ingeniería, Universidad Nacional de Colombia, Bogotá, Colombia, 2005.
dc.relation.references/*ref*/Ministerio de Ambiente, Vivienda y Desarrollo Territorial. Reglamento Colombiano de construcción sismo resistente. NSR-10. Bogotá, Colombia: Asociación Colombiana de Ingeniería Sísmica, 2010.
dc.subject.proposalpost-installed anchoreng
dc.subject.proposalhigh strength concreteeng
dc.subject.proposalanclaje posinstaladospa
dc.subject.proposalconcreto alta resistenciaspa


Archivos en el ítem

ArchivosTamañoFormatoVer

No hay archivos asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem